Rotary Actuator Vane Type Series CRB2BW
(With Auto Switch)
Single Vane Specifications
Size | 10 | 15 | 20 | 30 | 40 | |||
Rotating angle | 90°, 180°, 270° | |||||||
Fluid | Air (Non-lube) | |||||||
Proof pressure [MPa] | 1.05 | 1.5 | ||||||
Ambient and fluid temperature | 5 to 60°C | |||||||
Max. operating pressure [MPa] | 0.7 | 1.0 | ||||||
Min. operating pressure [MPa] | 0.2 | 0.15 | ||||||
Rotation time adjustment range s/90° Note 1) | 0.03~0.3 | 0.04~0.3 | 0.07~0.5 | |||||
Allowable kinetic energy [J] Note 2) | 0.00015 | 0.001 | 0.003 | 0.02 | 0.04 | |||
0.00025 | 0.0004 | 0.015 | 0.03 | |||||
Shaft load[N] | Allowable radial load | 15 | 15 | 25 | 30 | 60 | ||
Allowable thrust load | 10 | 10 | 20 | 25 | 40 | |||
Port location | Side ported or Axial ported | |||||||
Port size (Side ported, Axial ported) | M3 x 0.5 | M5 x 0.8 | ||||||
Angle adjustable range Note 3) | 0 to 230° | 0 to 240° | 0 to 230° |
Double Vane Specifications
Size | 10 | 15 | 20 | 30 | 40 | |||
Rotating angle | 90°, 100° | |||||||
Fluid | Air (Non-lube) | |||||||
Proof pressure [MPa] | 1.05 | 1.5 | ||||||
Ambient and fluid temperature | 5 to 60°C | |||||||
Max. operating pressure [MPa] | 0.7 | 1.0 | ||||||
Min. operating pressure [MPa] | 0.2 | 0.15 | ||||||
Rotation time adjustment range s/90° Note 1) | 0.03~0.3 | 0.04~0.3 | 0.07~0.5 | |||||
Allowable kinetic energy [J] | 0.0003 | 0.0012 | 0.0033 | 0.02 | 0.04 | |||
Shaft load[N] | Allowable radial load | 15 | 15 | 25 | 30 | 60 | ||
Allowable thrust load | 10 | 10 | 20 | 25 | 40 | |||
Port location | Side ported or Axial ported | |||||||
Port size (Side ported, Axial ported) | M3 x 0.5 | M5 x 0.8 | ||||||
Angle adjustable range Note 2) | 0 to 90° |